Electric generating plantEIA plant no. 60460

Chamon

Type
Natural Gas Fired Combustion Turbine
Nameplate capacity
121 MW
Units
2
In service since
2017
Operator
Peaker Power, LLC
Location
Houston, Harris County, Texas
Rated 508th largest in Texas · 2423rd of 14,761 in the U.S. · by nameplate

Chamon is a natural gas power plant in Texas with a nameplate capacity of 121 MW. It generates roughly 116.3k MWh per year — enough to power about 11,077 average U.S. homes.

Its capacity factor of 11% reflects intermittent or peaking operation. At 1354 lb CO₂/MWh, its emission rate sits above the national grid average of roughly 800 lb/MWh.

On paper vs. what it actually made

each square = 1 hour at full nameplate

Run flat out every hour of the year, Chamon could make 1.1M MWh. In 2023 it made 116.3k MWh — the same as running at full power 11 hours in every 100.

Nameplate, full year1.1M MWh121 MW × 8,760 hours
Actually generated116.3k MWhEPA eGRID, 2023 · ≈11,077 homes

Peaking or variableCapacity factor 11%. It runs only part of the time — when demand is high, or when the wind or sun allows.

How it works

A combustion turbine (“peaker”) burning natural gas

airnatural gas1compressor squeezes air2fuel burns3hot gas spins turbine4generator
  1. A compressor at the front squeezes outside air.
  2. natural gas burns in that compressed air.
  3. The hot, expanding gas spins the turbine — the same idea as a jet engine.
  4. The turbine turns a generator; exhaust leaves through the stack.

Why the numbers look like this: a combustion turbine can go from cold to full power in well under an hour, often minutes, so grid operators call on these plants for the few hottest or coldest hours of the year. A low capacity factor here is the job description, not a failure.

This plant highlighted in navy-ringed pin; other generators within 25 miles shown as fuel-colored dots.

Natural GasOilSolarBattery Storage

Location

Address18511 Beaumont Hwy
CityHouston
CountyHarris County
StateTexas
ZIP77049
Coordinates29.88321, -95.11135
OperatorPeaker Power, LLC

Generators (2)

IDTechnologyFuelNameplate capacityStatusOnline
CH1Natural Gas Fired Combustion TurbineNatural Gas60.5 MWOperating2017
CH2Natural Gas Fired Combustion TurbineNatural Gas60.5 MWOperating2017

Ownership

OwnerLocationShare
Chamon Power LLCPrinceton, NJ10000.0%

Ownership reported to EIA Form 860. Percentages reflect reported generator-level ownership share, averaged when a plant has multiple generators.

Emissions (annual)

CO₂78.8k metric tons
NOₓ8 metric tons
CO₂ Rate1354 lb/MWh
U.S. grid average800 lb/MWhNatural gas combined-cycle average900 lb/MWhThis plant1,354 lb/MWhCoal plant average2,100 lb/MWh

Annual totals and CO₂ rate reported by EPA eGRID for 2023. Reference averages are approximate U.S.-wide figures from the same dataset.

Grid context

NERC RegionTRE
Balancing AuthorityElectric Reliability Council of Texas, Inc.

About Natural Gas plants

Natural gas plants are the workhorse of the modern grid. Combined-cycle units achieve very high efficiency and can ramp up and down quickly to balance variable renewables. They emit roughly half the CO₂ per MWh of coal and far less of other pollutants, but they still release upstream methane during fuel extraction.

Other plants in Harris County

View all plants in Harris County →

Explore more