Electric generating plantEIA plant no. 54321

Chickadee G-3

Type
Natural Gas Fired Combustion Turbine
Nameplate capacity
34.8 MW
Units
5
In service since
1987–1999
Operator
Chickadee 3-G Purchaser LLC
Location
Beaumont, Jefferson County, Texas
Rated 673rd largest in Texas · 4438th of 14,761 in the U.S. · by nameplate

Chickadee G-3 is a natural gas power plant in Texas with a nameplate capacity of 34.8 MW. It generates roughly 259.1k MWh per year — enough to power about 24,673 average U.S. homes.

Its capacity factor of 85% means it runs nearly around-the-clock as baseload generation. At 643 lb CO₂/MWh, its emission rate sits below the national grid average of roughly 800 lb/MWh.

On paper vs. what it actually made

each square = 1 hour at full nameplate

Run flat out every hour of the year, Chickadee G-3 could make 304.8k MWh. In 2023 it made 259.1k MWh — the same as running at full power 85 hours in every 100.

Nameplate, full year304.8k MWh34.8 MW × 8,760 hours
Actually generated259.1k MWhEPA eGRID, 2023 · ≈24,673 homes

BaseloadCapacity factor 85%. It runs nearly around the clock.

Month by month in 2025

100% of nameplate0Jan: 9.4k MWh (36% of capacity)JFeb: 9.2k MWh (39% of capacity)FMar: 8.2k MWh (32% of capacity)MApr: 8.8k MWh (35% of capacity)AMay: 9.9k MWh (38% of capacity)MJun: 9.1k MWh (36% of capacity)JJul: 9.2k MWh (35% of capacity)JAug: 8.9k MWh (34% of capacity)ASep: 8.3k MWh (33% of capacity)SOct: 8.1k MWh (31% of capacity)ONov: 9.0k MWh (36% of capacity)NDec: 8.8k MWh (34% of capacity)D

Pale bars are each month's ceiling (34.8 MW nameplate × hours in the month). Filled bars are actual net generation reported to EIA Form 923.

How it works

A combustion turbine (“peaker”) burning natural gas

airnatural gas1compressor squeezes air2fuel burns3hot gas spins turbine4generator
  1. A compressor at the front squeezes outside air.
  2. natural gas burns in that compressed air.
  3. The hot, expanding gas spins the turbine — the same idea as a jet engine.
  4. The turbine turns a generator; exhaust leaves through the stack.

Why the numbers look like this: a combustion turbine can go from cold to full power in well under an hour, often minutes, so grid operators call on these plants for the few hottest or coldest hours of the year. A low capacity factor here is the job description, not a failure.

This plant highlighted in navy-ringed pin; other generators within 25 miles shown as fuel-colored dots.

Natural Gas

Location

AddressI-10 SW @ Smith Road
CityBeaumont
CountyJefferson County
StateTexas
ZIP77705
Coordinates29.97280, -94.21420
OperatorChickadee 3-G Purchaser LLC

Generators (5)

IDTechnologyFuelNameplate capacityStatusOnline
3N80Natural Gas Steam TurbineNatural Gas14.8 MWOperating1987
2N80Natural Gas Fired Combustion TurbineNatural Gas5.0 MWOperating1999
N802Natural Gas Fired Combustion TurbineNatural Gas5.0 MWOperating1999
N803Natural Gas Fired Combustion TurbineNatural Gas5.0 MWOperating1999
N804Natural Gas Fired Combustion TurbineNatural Gas5.0 MWOperating1999

Emissions (annual)

CO₂83.3k metric tons
SO₂1 metric tons
NOₓ83 metric tons
CO₂ Rate643 lb/MWh
This plant642 lb/MWhU.S. grid average800 lb/MWhNatural gas combined-cycle average900 lb/MWhCoal plant average2,100 lb/MWh

Annual totals and CO₂ rate reported by EPA eGRID for 2023. Reference averages are approximate U.S.-wide figures from the same dataset.

Grid context

NERC RegionSERC
Balancing AuthorityMidcontinent Independent Transmission System Operator, Inc..

About Natural Gas plants

Natural gas plants are the workhorse of the modern grid. Combined-cycle units achieve very high efficiency and can ramp up and down quickly to balance variable renewables. They emit roughly half the CO₂ per MWh of coal and far less of other pollutants, but they still release upstream methane during fuel extraction.

Other plants in Jefferson County

View all plants in Jefferson County →