Donald Von Raesfeld Power Plant is a natural gas power plant in California with a nameplate capacity of 154 MW. It generates roughly 862.1k MWh per year — enough to power about 82,104 average U.S. homes.
Its capacity factor of 64% puts it in the middle range — running steadily but not full-time. At 970 lb CO₂/MWh, its emission rate sits above the national grid average of roughly 800 lb/MWh.
Run flat out every hour of the year, Donald Von Raesfeld Power Plant could make 1.3M MWh. In 2023 it made 862.1k MWh — the same as running at full power 64 hours in every 100.
Mid-meritCapacity factor 64%. It runs much of the time, but not all of it.
Pale bars are each month's ceiling (154 MW nameplate × hours in the month). Filled bars are actual net generation reported to EIA Form 923.
How it works
Why the numbers look like this: reusing the exhaust heat is why combined-cycle plants turn roughly half or more of their fuel's energy into electricity, against about a third for a simple steam or turbine plant. Cheap to run, they usually sit in the middle of the dispatch order: on most days, off on some nights.
This plant highlighted in navy-ringed pin; other generators within 25 miles shown as fuel-colored dots.
| Address | 850 Duane Avenue |
|---|---|
| City | Santa Clara |
| County | Santa Clara County |
| State | California |
| ZIP | 95054 |
| Coordinates | 37.37670, -121.95080 |
| Operator | City of Santa Clara - (CA) |
| ID | Technology | Fuel | Nameplate capacity | Status | Online |
|---|---|---|---|---|---|
| STG | Natural Gas Fired Combined Cycle | Natural Gas | 54.0 MW | Operating | 2005 |
| CTG1 | Natural Gas Fired Combined Cycle | Natural Gas | 50.0 MW | Operating | 2005 |
| CTG2 | Natural Gas Fired Combined Cycle | Natural Gas | 50.0 MW | Operating | 2005 |
| CO₂ | 418.1k metric tons |
|---|---|
| SO₂ | 2 metric tons |
| NOₓ | 23 metric tons |
| CO₂ Rate | 970 lb/MWh |
Annual totals and CO₂ rate reported by EPA eGRID for 2023. Reference averages are approximate U.S.-wide figures from the same dataset.
| NERC Region | WECC |
|---|---|
| Balancing Authority | California Independent System Operator |
Natural gas plants are the workhorse of the modern grid. Combined-cycle units achieve very high efficiency and can ramp up and down quickly to balance variable renewables. They emit roughly half the CO₂ per MWh of coal and far less of other pollutants, but they still release upstream methane during fuel extraction.
| Data center | Distance |
|---|---|
| Lumen Santa Clara | 0.1 mi |
| Digital Realty Silicon Valley SJC11 | 0.1 mi |
| Colovore | 0.1 mi |
| Digital Realty Silicon Valley SJC10 | 0.1 mi |
| Lumen | 0.1 mi |
| Prime Santa Clara | 0.2 mi |
| Santa Clara Data Center (SJC3) | 0.2 mi |
| Digital Realty Silicon Valley SJC15 | 0.2 mi |
Data centers mapped on OpenStreetMap within 25 miles. A data center draws from the regional grid, so being near this plant doesn't mean it buys this plant's power. U.S. data center map