Okeechobee Clean Energy Center is a natural gas power plant in Florida with a nameplate capacity of 1,723 MW. It generates roughly 11.4M MWh per year — enough to power about 1,082,888 average U.S. homes.
Its capacity factor of 75% puts it in the middle range — running steadily but not full-time. At 739 lb CO₂/MWh, its emission rate sits below the national grid average of roughly 800 lb/MWh.
Run flat out every hour of the year, Okeechobee Clean Energy Center could make 15.1M MWh. In 2023 it made 11.4M MWh — the same as running at full power 75 hours in every 100.
Mid-meritCapacity factor 75%. It runs much of the time, but not all of it.
Pale bars are each month's ceiling (1,723 MW nameplate × hours in the month). Filled bars are actual net generation reported to EIA Form 923.
How it works
Why the numbers look like this: reusing the exhaust heat is why combined-cycle plants turn roughly half or more of their fuel's energy into electricity, against about a third for a simple steam or turbine plant. Cheap to run, they usually sit in the middle of the dispatch order: on most days, off on some nights.
This plant highlighted in navy-ringed pin; other generators within 25 miles shown as fuel-colored dots.
| Address | 3193 NE 366th Trail |
|---|---|
| City | Okeechobee |
| County | Okeechobee County |
| State | Florida |
| ZIP | 34972 |
| Coordinates | 27.63417, -80.79111 |
| Operator | Florida Power & Light Co |
| ID | Technology | Fuel | Nameplate capacity | Status | Online |
|---|---|---|---|---|---|
| 1ST | Natural Gas Fired Combined Cycle | Natural Gas | 593 MW | Operating | 2019 |
| 1A | Natural Gas Fired Combined Cycle | Natural Gas | 377 MW | Operating | 2019 |
| 1B | Natural Gas Fired Combined Cycle | Natural Gas | 377 MW | Operating | 2019 |
| 1C | Natural Gas Fired Combined Cycle | Natural Gas | 377 MW | Operating | 2019 |
| CO₂ | 4.2M metric tons |
|---|---|
| SO₂ | 21 metric tons |
| NOₓ | 243 metric tons |
| CO₂ Rate | 739 lb/MWh |
Annual totals and CO₂ rate reported by EPA eGRID for 2023. Reference averages are approximate U.S.-wide figures from the same dataset.
| NERC Region | SERC |
|---|---|
| Balancing Authority | Florida Power & Light Company |
Natural gas plants are the workhorse of the modern grid. Combined-cycle units achieve very high efficiency and can ramp up and down quickly to balance variable renewables. They emit roughly half the CO₂ per MWh of coal and far less of other pollutants, but they still release upstream methane during fuel extraction.