Electric generating plantEIA plant no. 7920

Traer South

Type
Petroleum Liquids
Nameplate capacity
2.0 MW
Units
1
In service since
2001
Operator
City of Traer - (IA)
Location
Traer, Tama County, Iowa
Rated 257th largest in Iowa · 11103rd of 14,761 in the U.S. · by nameplate

Traer South is a oil power plant in Iowa with a nameplate capacity of 2.0 MW.

The 2.0 MW is nameplate capacity: the most this plant's generators are rated to produce, not what it actually generates. EPA eGRID reports no positive net generation for it this year.

How it works

A reciprocating-engine plant

oil1pistons fire like a car engine2generator
  1. oil burns in cylinders, driving pistons — the same principle as a truck engine, much larger.
  2. The crankshaft turns a generator.
  3. Plants are built from several identical engines, so they can run one at a time or all together.

Why the numbers look like this: engines start in minutes and come in small blocks, so they show up at landfills, on islands and as backup or peaking units — places that need power in small, fast pieces.

This plant highlighted in navy-ringed pin; other generators within 25 miles shown as fuel-colored dots.

Natural GasOilWindSolar

Location

AddressHwy 63 South
CityTraer
CountyTama County
StateIowa
ZIP50675
Coordinates42.19250, -92.47470
OperatorCity of Traer - (IA)

Generators (1)

IDTechnologyFuelNameplate capacityStatusOnline
5Petroleum LiquidsDistillate Oil2.0 MWStandby2001

Grid context

NERC RegionMRO
Balancing AuthorityMidcontinent Independent Transmission System Operator, Inc..

About Oil plants

Oil-fired plants typically run only during peak demand or grid emergencies because oil is expensive compared to gas and coal. Per megawatt-hour, they emit nearly as much CO₂ as coal.