Agnews Power Plant is a natural gas power plant in California with a nameplate capacity of 32.0 MW. It generates roughly 35.7k MWh per year — enough to power about 3,404 average U.S. homes.
Its capacity factor of 13% reflects intermittent or peaking operation. At 1203 lb CO₂/MWh, its emission rate sits above the national grid average of roughly 800 lb/MWh.
Run flat out every hour of the year, Agnews Power Plant could make 280.3k MWh. In 2023 it made 35.7k MWh — the same as running at full power 13 hours in every 100.
Peaking or variableCapacity factor 13%. It runs only part of the time — when demand is high, or when the wind or sun allows.
Pale bars are each month's ceiling (32.0 MW nameplate × hours in the month). Filled bars are actual net generation reported to EIA Form 923.
How it works
Why the numbers look like this: reusing the exhaust heat is why combined-cycle plants turn roughly half or more of their fuel's energy into electricity, against about a third for a simple steam or turbine plant. Cheap to run, they usually sit in the middle of the dispatch order: on most days, off on some nights.
This plant highlighted in navy-ringed pin; other generators within 25 miles shown as fuel-colored dots.
| Address | 3800 Cisco Way |
|---|---|
| City | San Jose |
| County | Santa Clara County |
| State | California |
| ZIP | 95134 |
| Coordinates | 37.40580, -121.92720 |
| Operator | OLS Energy-Agnews Inc. |
| ID | Technology | Fuel | Nameplate capacity | Status | Online |
|---|---|---|---|---|---|
| GEN1 | Natural Gas Fired Combined Cycle | Natural Gas | 24.4 MW | Operating | 1990 |
| GEN2 | Natural Gas Fired Combined Cycle | Natural Gas | 7.6 MW | Operating | 1990 |
| CO₂ | 21.5k metric tons |
|---|---|
| NOₓ | 58 metric tons |
| CO₂ Rate | 1203 lb/MWh |
Annual totals and CO₂ rate reported by EPA eGRID for 2023. Reference averages are approximate U.S.-wide figures from the same dataset.
| NERC Region | WECC |
|---|---|
| Balancing Authority | California Independent System Operator |
Natural gas plants are the workhorse of the modern grid. Combined-cycle units achieve very high efficiency and can ramp up and down quickly to balance variable renewables. They emit roughly half the CO₂ per MWh of coal and far less of other pollutants, but they still release upstream methane during fuel extraction.
| Data center | Distance |
|---|---|
| CoreSite SV2 | 0.6 mi |
| Dell 350 Holger Way | 1.2 mi |
| Stack Infrastructure data center, San Jose | 1.9 mi |
| STACK Infrastructure | 2.0 mi |
| NTT Limited data center, 2334 Lundy Place, San Jose | 2.1 mi |
| DataBank Santa Clara SFO1 | 2.1 mi |
| Equinix San Jose SV3 | 2.5 mi |
| XO Fremont | 4.8 mi |
Data centers mapped on OpenStreetMap within 25 miles. A data center draws from the regional grid, so being near this plant doesn't mean it buys this plant's power. U.S. data center map