American Crystal Sugar Moorhead is a coal power plant in Minnesota with a nameplate capacity of 5.0 MW. It generates roughly 39.8k MWh per year — enough to power about 3,793 average U.S. homes.
Its capacity factor of 91% means it runs nearly around-the-clock as baseload generation. At 1217 lb CO₂/MWh, its emission rate sits above the national grid average of roughly 800 lb/MWh.
Run flat out every hour of the year, American Crystal Sugar Moorhead could make 43.8k MWh. In 2023 it made 39.8k MWh — the same as running at full power 91 hours in every 100.
BaseloadCapacity factor 91%. It runs nearly around the clock.
Pale bars are each month's ceiling (5.0 MW nameplate × hours in the month). Filled bars are actual net generation reported to EIA Form 923.
How it works
Why the numbers look like this: a boiler and turbine this size take hours to bring up from cold, so steam plants were built to run steadily for long stretches. A steam plant with a low capacity factor is usually being held in reserve, or run only through the hottest and coldest weeks.
This plant highlighted in navy-ringed pin; other generators within 25 miles shown as fuel-colored dots.
| Address | 2500 North 11th |
|---|---|
| City | Moorhead |
| County | Clay County |
| State | Minnesota |
| ZIP | 56560 |
| Coordinates | 46.90260, -96.76112 |
| Operator | American Crystal Sugar Co |
| ID | Technology | Fuel | Nameplate capacity | Status | Online |
|---|---|---|---|---|---|
| G1 | Conventional Steam Coal | Subbituminous Coal | 3.0 MW | Operating | 1948 |
| G2 | Conventional Steam Coal | Subbituminous Coal | 2.0 MW | Operating | 1961 |
| CO₂ | 24.2k metric tons |
|---|---|
| SO₂ | 10 metric tons |
| NOₓ | 30 metric tons |
| CO₂ Rate | 1217 lb/MWh |
Annual totals and CO₂ rate reported by EPA eGRID for 2023. Reference averages are approximate U.S.-wide figures from the same dataset.
| NERC Region | MRO |
|---|---|
| Balancing Authority | Southwest Power Pool |
Coal plants burn pulverized coal to boil water and spin steam turbines. They emit substantial CO₂, SO₂, and NOₓ along with mercury and particulate matter. Modern units include scrubbers and selective catalytic reduction; older units are increasingly being retired or converted to natural gas as economics shift.
| Data center | Distance |
|---|---|
| Dakota Carrier Network | 7.2 mi |
| Applied Digital | 7.3 mi |
Data centers mapped on OpenStreetMap within 25 miles. A data center draws from the regional grid, so being near this plant doesn't mean it buys this plant's power. U.S. data center map