Arthur Kill Generating Station is a natural gas power plant in New York with a nameplate capacity of 878 MW. It generates roughly 1.0M MWh per year — enough to power about 99,459 average U.S. homes.
Its capacity factor of 13% reflects intermittent or peaking operation. At 1339 lb CO₂/MWh, its emission rate sits above the national grid average of roughly 800 lb/MWh.
Run flat out every hour of the year, Arthur Kill Generating Station could make 7.8M MWh. In 2023 it made 1.0M MWh — the same as running at full power 13 hours in every 100.
Peaking or variableCapacity factor 13%. It runs only part of the time — when demand is high, or when the wind or sun allows.
Pale bars are each month's ceiling (878 MW nameplate × hours in the month). Filled bars are actual net generation reported to EIA Form 923.
How it works
Why the numbers look like this: a boiler and turbine this size take hours to bring up from cold, so steam plants were built to run steadily for long stretches. A steam plant with a low capacity factor is usually being held in reserve, or run only through the hottest and coldest weeks.
This plant highlighted in navy-ringed pin; other generators within 25 miles shown as fuel-colored dots.
| Address | 4401 Victory Blvd |
|---|---|
| City | Staten Island |
| County | Richmond County |
| State | New York |
| ZIP | 10314 |
| Coordinates | 40.59156, -74.20003 |
| Operator | Arthur Kill Power, LLC |
| ID | Technology | Fuel | Nameplate capacity | Status | Online |
|---|---|---|---|---|---|
| 3 | Natural Gas Steam Turbine | Natural Gas | 536 MW | Operating | 1969 |
| 2 | Natural Gas Steam Turbine | Natural Gas | 342 MW | Operating | 1959 |
| Owner | Location | Share |
|---|---|---|
| Arthur Kill Power LLC | Staten Island, NY | 10000.0% |
Ownership reported to EIA Form 860. Percentages reflect reported generator-level ownership share, averaged when a plant has multiple generators.
| CO₂ | 699.3k metric tons |
|---|---|
| SO₂ | 4 metric tons |
| NOₓ | 411 metric tons |
| CO₂ Rate | 1339 lb/MWh |
Annual totals and CO₂ rate reported by EPA eGRID for 2023. Reference averages are approximate U.S.-wide figures from the same dataset.
| NERC Region | NPCC |
|---|---|
| Balancing Authority | New York Independent System Operator |
Natural gas plants are the workhorse of the modern grid. Combined-cycle units achieve very high efficiency and can ramp up and down quickly to balance variable renewables. They emit roughly half the CO₂ per MWh of coal and far less of other pollutants, but they still release upstream methane during fuel extraction.
| Data center | Distance |
|---|---|
| Telehouse Teleport | 1.7 mi |
| Merrill Lynch Data Center | 1.8 mi |
Data centers mapped on OpenStreetMap within 25 miles. A data center draws from the regional grid, so being near this plant doesn't mean it buys this plant's power. U.S. data center map